TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 153 of 928
TM 9-2350-277-20-5 SERVICE HYDRAULIC RESERVOIR BREATHER 0670 00 THIS WORK PACKAGE COVERS: Removal (page 0670 00-1). Cleaning (page 0670 00-2). Installation (page 0670 00-2). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0926 00, Item 65) M a t e r i a l s / P a r t s Cleaning Compound (WP 0928 00, Item 19) Sealing compound (WP 0928 00, Item 56) P e r s o n n e l R e q u i r e d Unit Mechanic R e f e r e n c e s See your -10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Power plant upper rear access panel removed (see your -10) REMOVAL WARNING Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested. Do not service hydraulic system when FRH is hot or pressurized. Wear gloves and avoid contact with skin. If FRH contacts skin, wash immediately with soap. If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention. If FRH is swallowed, get medical attention. NOTE Breather must be serviced every 75 hours, 750 miles (1200 km), or semi-annually. 0670 00-1