TM 9-2350-277-20-5 REPLACE POWER PLANT HYDRAULIC HOSES — Continued 0668 00 FOLLOW-THROUGH STEPS 1. Install power plant (WP 0156 00). 2. Fill hydraulic tank (WP 0155 00). WARNING Unlocked ramp can fall open suddenly. Personnel can be killed or injured. Do not stand behind ramp. Keep away from ramp during testing and bleeding of hydraulic lines. 3. Start engine (see your -10). 4. Check for hydraulic leaks. 5. Raise and lower ramp several times to bleed air from system. 6. Raise and lock ramp (see your -10). 7. Stop engine (see your -10). END OF TASK 0668 00-5/6 blank