TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 134 of 928
TM 9-2350-277-20-5 REPLACE HOSE FROM BULKHEAD CONNECTION TO RAMP CYLINDER — Continued 0665 00 FOLLOW-THROUGH STEPS 1. Check fluid level in tank. Add fluid as needed (see your 10). WARNING Wearing loose clothing around moving parts can allow personnel to get caught and could result in injury or death. Tuck in loose clothing. WARNING Unlocked ramp can fall open suddenly. Personnel can be killed or injured. Do not stand behind ramp. Keep away from ramp during testing and bleeding of hydraulic lines. 2. Start engine (see your -10). Check for hydraulic leaks. 3. Raise and lower ramp several times to bleed air from system (see your -10). 4. Install power plant rear access panel (WP 0439 00). 5. Install floor plates (WP 0539 00). 6. Lower tread plate on mortar base plate. 7. Raise and lock ramp (see your -10). 8. Stop engine (see your -10). END OF TASK 0665 00-4