TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 130 of 928

TM 9-2350-277-20-5 REPLACE TUBE FROM RAMP CONTROL VALVE TO BULKHEAD — Continued 0664 00 FOLLOW-THROUGH STEPS 1. Check fluid level in hydraulic tank (WP 0155 00). WARNING Wearing loose clothing around moving parts can allow personnel to get caught and result in injury or death. Tuck in loose clothing. WARNING Unlocked ramp can fall open suddenly. Personnel can be killed or injured. Do not stand behind ramp. Keep away from ramp during testing and bleeding of hydraulic lines. 2. Start engine (see your -10). 3. Check for hydraulic leaks. 4. Raise and lower ramp several times to bleed air from system. 5. Install driver’s power plant access panel (see your -10). 6. Raise and lock ramp (see your -10). 7. Stop engine (see your -10). 8. Install left front floor plate (WP 0453 00). END OF TASK 0664 00-4