TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 128 of 928
TM 9-2350-277-20-5 REPLACE TUBE FROM RAMP CONTROL VALVE TO BULKHEAD — Continued 0664 00 WARNING Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested. Do not service hydraulic system when FRH is hot or pressurized. Wear gloves and avoid contact with skin. If FRH contacts skin, wash immediately with soap. If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention. If FRH is swallowed, get medical attention. 3. Remove tube (5) from tee or elbow (6) at ramp control valve (7). 4. Remove tube (5) from bulkhead nipple (8). 5. Remove hose (9) from bulkhead nipple (8). 6. Remove jam nut (10) from nipple (8) and remove nipple from bulkhead. 0664 00-2