TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 119 of 928

TM 9-2350-277-20-5 REPLACE RAMP CONTROL VALVE (WITH INTERNAL RELIEF VALVE) AND FITTINGS — Continued 0661 00 8. Connect elbow (5) with hose (6) to elbow (7). 9. Connect quick disconnect (8) on hose (9) to quick disconnect (10) on valve (2). 10. Connect tube (11) to elbow (12) on valve (2). FOLLOW-THROUGH STEPS 1. Fill hydraulic reservoir (WP 0155 00). 2. Install drivers access panel (see your -10). 3. Raise and lower ramp several times to bleed system and check for leaks (see your -10). 4. Raise and lock ramp (see your -10). END OF TASK 0661 00-7/8 blank