TM-9-2350-277-20-4 Unit Maintenance Manual Volume 4 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 446 of 884
TM 9-2350-277-20-4 ADJUST RAMP LOCK (M577A3 AND M1068A3 ONLY) — Continued 0522 00 NOTE After attaching clevis to the arm, make sure arm (3) is still against the setscrews. 9. Align clevis (5) with arm (6). Secure with headed pin (7) and new cotter pin (8). 10. Loosen two nuts (9) on cable (10) at bracket (11). 11. Adjust length of cable (10) to obtain 1-7/8 inches (5 cm) clearance between nut (12) and seal (13). Tighten two nuts (9). 0522 00-4