TM 9-2350-277-20-4 REPLACE TURBINE ACCESS DOOR HINGES (M58 ONLY) — Continued 0487 00 INSTALLATION 1. Assemble four hinge halves (8) and install two shoulder pins (6), washers (7), and new cotter pins (5). Install washers as required to take up excess space between hinge halves (8). 2. Apply sealing compound to screws before installing in hinges. 3. Install two hinges (3), eight washers (2), and screws (1) on turbine access door (4) and carrier. END OF TASK 0487 00-3/4 blank Change 1