TM-9-2350-277-20-4 Unit Maintenance Manual Volume 4 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 285 of 884
TM 9-2350-277-20-4 REPLACE POWER PLANT DOOR COMBAT LOCK — Continued 0473 00 INSTALLATION 1. (H) Install bolt (1) in place from outside carrier through access to power plant compartment. 2. From inside driver’s compartment, install spring (2) and handle (3) on bolt (1). Secure with new drive pin (4). 3. Connect four wiring harnesses (5) to bulkhead in driver’s compartment. FOLLOW-THROUGH STEPS 1. Connect battery ground strap(WP 0337 00), (WP 0338 00), or (WP 0339 00). 2. Close power plant door (see your -10). 3. Connect and raise trim vane (see your -10). END OF TASK 0473 00-3/4 blank