TM 9-2350-277-20-4 REPLACE POWER PLANT DOOR (M113A3 ONLY) — Continued 0470 00 NOTE If housing is aligned with wrong holes there could be too much tension when the power plant door armor is not installed, or too little tension when the power plant door armor is installed. 9. Install nine springs (6) in square opening in left bracket (5). Raise door (2) until housing (10) can be installed. Align housing with holes on bracket (5) by moving the door back and forth. 10. Secure housing (10) with two screws (11) and washers (12). 11. Remove lifting device from power plant door. FOLLOW-THROUGH STEPS 1. Close and lock power plant door (see your -10). 2. Connect and raise trim vane (see your -10). END OF TASK 0470 00-4