TM-9-2350-277-20-4 Unit Maintenance Manual Volume 4 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 256 of 884
TM 9-2350-277-20-4 RAISE AND LOWER POWER PLANT GRILLE — Continued 0464 00 C A U T I O N Be sure to use strap installed in step (11) to guide power plant access door while grill is being lowered. NOTE Before lowering grill, apply caulking compound to metal joints between hull and lower support of grill to assure water tightness. 3. With lifting device still attached to grill (6), remove screw (7), locknut (8), and brace (9) from two lugs (10). 4. Stow brace (9) to lug (10) with screw (7) and locknut (8). 0464 00-12