TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 88 of 962
TM 9-2350-277-20-3 REPLACE UTILITY OUTLET RECEPTACLE — Continued 0265 00 4. Remove two screws (10), lockwashers (11), and receptacle (12) from master switch panel (8). Discard lockwashers. 5. If needed, remove grommet (13) from master switch panel (8). INSPECTION-ACCEPTANCE AND REJECTION CRITERIA 1. Check connectors. Replace cracked or broken connector (WP 0382 00). INSTALLATION 1. If removed, install new grommet (1) from master switch panel (2). NOTE Make sure receptacle cover retaining chain is installed on lower screw. 2. Place utility outlet receptacle (3) on rear of panel (2). Secure with two new lockwashers (4) and screws (5). 3. Route utility outlet receptacle lead (6) through grommet (1). Install shell connector (7) and slotted washer (8). 0265 00-2 Change 2