TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 85 of 962
TM 9-2350-277-20-3 REPLACE NATO AUXILIARY POWER (SLAVE) RECEPTACLE (M577A3 AND M1068A3 ONLY) — Continued 0264 00 INSTALLATION 1. Install insulator bushing (1) in hull. 2. Install receptacle (2), new gasket (3), insulator (4), adapter (5), and new gasket (6). 3. Connect circuit 6 lead (7) to positive terminal of receptacle (2) with new lockwasher (8) and screw (9). 4. Connect circuit 50 lead (10) to negative terminal of receptacle (2) with new lockwasher (11) and screw (12). 5. Position new gasket (6) and adapter (5) on hull and secure with four screws (13), new lockwashers (14), and washers (15). 6. Align receptacle (2), new gasket (3), and insulator (4) with adapter (5). Install four screws (16), new lockwashers (17), and washers (18). 7. Place circuit 50 lead (10) and clamp (19) on hull weldnut. Secure with washer (20) and screw (21). 8. Position harness protector (22) and secure with seven screws (23) new lockwashers (24), and washers (25). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0338 00). END OF TASK 0264 00-3/4 blank Change 2