TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 694 of 962

TM 9-2350-277-20-3 REPAIR WIRING HARNESS — Continued 0382 00 e. Heat shrink those leads with insulated sleeving (1) on terminal (2). 4. Install multiple connectors the same way as single connectors. See Step 1 and Step 2 above. 5. If removed, install Y-type adapters and dummy plugs. a. Install Y-type adapter (3) on harness leads (4). b. Install dummy plugs (5) in male or female connector (6). FOLLOW-THROUGH STEPS 1. Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00). 2. Turn MASTER SWITCH to ON (see your -10). 3. Check for proper wiring harness repair. 4. Turn MASTER SWITCH to OFF (see your -10). END OF TASK 0382 00-6