TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 681 of 962

TM 9-2350-277-20-3 REPLACE AUXILIARY POWER (SLAVE) RECEPTACLE GROUND LEAD (M113A3, M1059A3, M1064A3, AND M58 ONLY) — Continued 0379 00 INSTALLATION 1. Install new grommet (2) on ground lead (1). Route lead through master switch panel (3). Install grommet in panel. 2. Install new lockwasher (4), ground lead (1), lead (5), washer (6), and new locknut (7). Tighten locknut. 3. Install ground lead (1) on negative post (8) of auxiliary power receptacle (9). Secure with screw (10) and lockwasher (11). 0379 00-3 Change 2