TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 680 of 962

TM 9-2350-277-20-3 REPLACE AUXILIARY POWER (SLAVE) RECEPTACLE GROUND LEAD (M113A3, M1059A3, M1064A3, AND M58 ONLY) — Continued 0379 00 2. Remove screw (6), lockwasher (7), and ground lead (8) from negative post (9) of auxiliary power receptacle (10). Do not discard lockwasher. 3. Remove locknut (11), washer (12), lead (13), ground lead (8), and lockwasher (14) from instrument panel hull strut mount (15). Discard locknut and lockwasher. 4. Remove ground lead (1) and grommet (2) from master switch panel (3). Discard grommet. 0379 00-2 Change 2