TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 674 of 962
TM 9-2350-277-20-3 REPLACE UTILITY OUTLET LEAD ASSEMBLY (M577A3 AND M1068A3 ONLY) — Continued 0377 00 INSPECTION-ACCEPTANCE AND REJECTION CRITERIA INSPECTION AND REPAIR 1. Check connectors. Repair as needed (WP 0382 00). INSTALLATION NOTE Lead assembly is banded as circuit 37 at master switch panel and circuit 38 at instrument panel. Make sure it is installed properly. 1. Connect lead assembly (1) to circuit 38 lead (4) at instrument panel (5). 2. Connect lead assembly (1) to circuit 37 lead (2) at master switch panel (3). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0338 00). 2. Turn MASTER SWITCH to ON to check that lead assembly is installed properly (see your -10). 3. Turn MASTER SWITCH to OFF (see your -10). END OF TASK 0377 00-2