TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 660 of 962

TM 9-2350-277-20-3 REPLACE RIGHT HEADLIGHT WIRING HARNESS — Continued 0373 00 8. Connect leads 514 (10) and 515 (11) to infrared headlamps (12). 9. Connect lead 25 (13) to horn (14). 10. Connect lead 20 (15) to marker lamp (16). 11. Bend and tape leads 17 and 18 (17) and (18) as shown. Connect leads to service headlamps (19). FOLLOW-THROUGH STEPS 1. Lower power plant grill (WP 0464 00). 2. Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00). 3. Close power plant access door (see your -10). 4. Raise trim vane (see your -10). END OF TASK 0373 00-6