TM 9-2350-277-20-3 REPLACE BATTERY-TO-RADIO WIRING HARNESS (LEFT SIDE) (M113A3 AND M1059A3 ONLY) — Continued 0369 00 REMOVAL NOTE On M113A3 only, there are two circuit 48 leads connected to positive terminal of third battery. Replace circuit 48 lead which runs along hull to capacitor located above battery boxes. 1. Remove nut (1), screw (2), positive jumper lead (3), circuit 772 lead (4), circuit 778 lead (5), circuit 48 lead (6), and M113A3 only circuit 48 lead (7) from positive terminal (8) of third battery (9). 0369 00-2 Change 2