TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 635 of 962
TM 9-2350-277-20-3 REPLACE DRIVER’S NIGHT VISION (DNV) (AN/VVS-2) POWER SUPPLY CABLE ASSEMBLY (ALL EXCEPT M58) — Continued 0368 00 INSTALLATION 1. For stowed position, connect circuit 517 lead (1) to the master switch panel dummy connector (3). 2. For operating position, connect circuit 517 lead (1) to the bottom of periscope (2). FOLLOW-THROUGH STEPS 1. Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00). END OF TASK 0368 00-3/4 blank