TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 502 of 962
TM 9-2350-277-20-3 12. Install new grommet (1) on circuit 400 lead (2). Route lead into distribution box (3). 13. Install circuit 6 (4), 2 (5), and 400 (6) leads on conductor bus (7) of master switch panel (8). Secure with new locknut (9). 14. Install circuit 2A lead (10) on conductor bus (7) of master switch panel (8). Secure with new lockwasher (11) and nut (12). 0362 00-24 Change 2 0362 00 REPLACE REAR MAIN WIRING HARNESS (M113A3, M1059A3, AND M58) — Continued