TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 498 of 962
TM 9-2350-277-20-3 49. Disconnect circuit 30 (20) and 31 (21) leads from fuel level gage switch (22). 50. Disconnect circuit 451B lead (1) from rear bilge pump on indicator light (2). 51. Disconnect circuit 450 (3), 450B (4), and 451A (5) leads from bilge pump switch (6). 52. Disconnect circuit 38 lead (7) from special purpose cable assembly (8). 53. Disconnect circuit 21 (9), 22 (10), 23 (11), and 24 (12) leads from front main wiring harness (13). 54. Remove rear main wiring harness (14) from carrier. 0362 00-20 Change 2 0362 00 REPLACE REAR MAIN WIRING HARNESS (M113A3, M1059A3, AND M58) — Continued