TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 468 of 962
T M 9 -- 2350 -- 277 -- 20 -- 3 0359 01--4 REPLACE VARIABLE SPEED FAN DRIVE WIRING HARNESS, 3W1 (NEW CONFIGURATION) -- Continued 0359 01 6. Connect plug P1 (2) and plug P2 (3) on variable speed fan controller jacks J1 (4) and J2 (5). 7. Install new tie straps (1) as required to secure wiring harness to engine. FOLLOW--THROUGH STEPS 1. Connect battery ground strap (WP 0337 00 or WP 0338 00). 2. Install driver’s power plant access panel (see your-10). 3. Install power plant rear access panels (see your -10). END OF TASK Change 2