TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 449 of 962
TM 9-2350-277-20-3 REPLACE BATTERY TO MASTER SWITCH LEAD (CIRCUIT 6) (M1064A3 ONLY) — Continued 0358 00 4. Route circuit 6 lead (1) below two clamps (2) on upper left wall. 5. Install two clamps (3) on circuit 6 lead (1). Secure, along with clamps (2), to two hull weldnuts with two screws (4) and new lockwashers (5). 6. Install clamp (3) with circuit 6 lead (2) on weldnut with screw (1) and new lockwasher (15). 0358 00-7