TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 447 of 962
TM 9-2350-277-20-3 REPLACE BATTERY TO MASTER SWITCH LEAD (CIRCUIT 6) (M1064A3 ONLY) — Continued 0358 00 7. Route circuit 6 lead (1) and grommet (2) out of master switch panel (3). Discard grommet. Remove lead from carrier. INSTALLATION 1. Install new grommet (2) on circuit 6 lead (1). Install lead and grommet in master switch panel (3). 0358 00-5