TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 446 of 962
TM 9-2350-277-20-3 REPLACE BATTERY TO MASTER SWITCH LEAD (CIRCUIT 6) (M1064A3 ONLY) — Continued 0358 00 5. Remove eight locknuts (7), screws (8), washers (9), and master switch panel (10) from distribution box (11). Discard locknuts. 6. Remove nut (12), screw (13), and circuit 6 lead (2) from conductor bus (14) in master switch panel (10). 0358 00-4