Page 39 of 962
TM 9-2350-277-20-3 REPLACE GENERATOR/BRACKET — Continued 0255 00 NOTE The pulley locknut must be tightened. Follow Steps 2 - 6. Performing these steps will lock the shaft in place with no damage. After the locknut is tightened, the generator is ready to be installed. 2. Loop the pulley belt (1) on the bottom groove of the pulley (2) 3. Cross the pulley belt (1) and put the other loop on the top grove of the pulley (2). 0255 00-5