TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 370 of 962
TM 9-2350-277-20-3 REPLACE BATTERY LEADS AND TERMINALS (RIGHT SIDE) (M1064A3 ONLY) — Continued 0344 00 C A U T I O N Do not start carriers while batteries are disconnected. Starting engine with outside power while batteries are disconnected will damage electrical components in the regulator. 1. Remove circuit 6N lead (1) or 6P lead (2) as follows: a. Remove tiedown strap (3) from circuit 6N lead (1) and 6P lead (2). b. Remove nut (4), screw (5), and lead (1) or (2) from terminal lug (6). c. Remove lead and grommet (7) from battery compartment. Discard grommet. 0344 00-2