TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 304 of 962

TM 9-2350-277-20-3 REPLACE FUEL RETURN PRESSURE TRANSDUCER — Continued 0325 00 INSTALLATION 1. Apply a thin coat of adhesive to threads of transducer (3). 2. Connect transducer (3) to tee (4). 3. Connect fuel return pressure transducer lead (1) to STE/ICE wiring harness (2). FOLLOW-THROUGH STEPS 1. Lower power plant grill (WP 0464 00). 2. Install air cleaner (WP 0168 00). 3. Close power plant front access door (see your -10). 4. Raise trim vane (see your -10). END OF TASK 0325 00-2