TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 300 of 962
TM 9-2350-277-20-3 REPLACE GENERATOR FIELD PRESSURE SWITCH — Continued 0323 00 INSTALLATION 1. Coat threads of switch with sealing compound. 2. Install switch (2) on tee (3) on secondary fuel filter (4). 3. Connect circuit 1A/1B lead (1) to switch (2). FOLLOW-THROUGH STEPS 1. Check operation of field switch (WP 0025 00). 2. Install driver’s power plant access panel (see your -10). END OF TASK 0323 00-2