TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 221 of 962

TM 9-2350-277-20-3 REPLACE SOLID STATE INFRARED POWER SUPPLY 0297 00 THIS WORK PACKAGE COVERS: Removal (page 0297 00-1). Installation (page 0297 00-3). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0926 00, Item 65) M a t e r i a l s / P a r t s Lockwasher (8) P e r s o n n e l R e q u i r e d Unit Mechanic R e f e r e n c e s See your -10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Battery ground strap disconnected (WP 0337 00), (WP 0338 00), or (WP 0339 00) REMOVAL WARNING High voltage in the M19 periscope can cause serious injury or death. To avoid accidents: ALWAYS connect power cableto M19 periscope BEFORE turning MASTER SWITCH and IR POWER switch ON. After turning IR POWER and MASTER switches OFF, ALWAYS wait at least 2 minutes BEFORE disconnecting power cable from M19 periscope. NEVER touch the end of the cable. Voltage could exceed 16,000 volts. 0297 00-1