TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 211 of 962

TM 9-2350-277-20-3 REPLACE INSTRUMENT PANEL MOUNTS AND GROUND LEAD (ALL EXCEPT M58) — Continued 0295 00 3. Tip instrument panel forward and remove two screws (1), ground lead (2), WAIT indicator ground lead (26) (glow plug system only), two lockwashers (3), and resilient mounts (4) from instrument panel. Discard lockwashers. 4. Remove nut (5), washer (6), lockwasher (7), ground lead (8), ground lead (9), screw (10), washer (11), and long strut (12) from hull mounts. Discard lockwasher. 5. Remove nut (13), washers (14), screw (15), washer (16), and strut (17) from hull mount. 0295 00-3 Change 1