TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 192 of 962
TM 9-2350-277-20-3 REPLACE INSTRUMENT PANEL SPECIAL PURPOSE CABLE — Continued 0290 00 18. Install ground lead (12) and new lockwasher (13) on upper support (14). 19. Install instrument panel (15) with two mounts (16) on support (14). Secure with two screws (17) and washers (18). 20. Install panel (15) on two struts (19). Secure with two nuts (20), mounts (21) and (22), washers (23), and screws (24). FOLLOW-THROUGH STEPS 1. Connect cables to speedometer and tachometer (WP 0859 00) and (WP 0862 00). 2. Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00). 3. Turn MASTER SWITCH to ON (see your -10). 4. Check gages and insure lights work (see your -10). 5. Turn MASTER SWITCH to OFF (see your -10). END OF TASK 0290 00-8 Change 1