TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 161 of 962

TM 9-2350-277-20-3 REPLACE INSTRUMENT PANEL ON-OFF SWITCHES — Continued 0282 00 INSTALLATION 1. Place toggle switch (2) on rear of instrument panel. Secure with guard (5) (DNV-POWER switch only), two new lockwashers (4), and screws (3). NOTE Make sure circuit leads are connected to correct switches. See Table of Contents for applicable wiring diagram. 2. Connect circuit leads (1) to rear of toggle switch (2). 0282 00-3