TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 156 of 962
TM 9-2350-277-20-3 REPLACE CIRCUIT BREAKER — Continued 0280 00 INSTALLATION 1. Place circuit breaker (3) on rear of instrument panel. Secure with two screws (5) and new locknuts (4). 2. Connect circuit 27 lead (2) and circuit 10 lead (1) to circuit breaker (3). FOLLOW-THROUGH STEPS 1. Install instrument panel (WP 0295 00). 2. Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00). 3. Turn MASTER SWITCH to ON (see your -10). MASTER SWITCH ON light should come on (see your -10). 4. Turn MASTER SWITCH to OFF (see your -10). END OF TASK 0280 00-2