TM 9-2350-277-20-3 REPLACE INSTRUMENT PANEL ASSEMBLY (ALL EXCEPT M58) — Continued 0279 00 8. Disconnect lead 14B (1) from start switch lead 14 (2). 9. Disconnect lead 74 (3) and lead 14 (2) from start switch (4). 10. Disconnect front main harness 516A lead (5) and special purpose harness lead 516 (6) from IR POWER or DTV (M58 only) switch (7). 11. Disconnect lead 514/515 (8), lead 520 (9), and lead 19 (10) from infrared blackout switch (11). 12. Disconnect battery/generator harness lead 27E (12) from battery/generator gauge (13). 13. Disconnect battery/generator harness lead 10 or lead 10A (M58 only) (14) and special purpose harness lead 27 (15) from circuit breaker (16). 14. Disconnect lead 31 (17) and lead 30 (18) from fuel tank switch (19) (except on M577A3 and M1068A3 carriers). 15. Disconnect lead 406 (20) and special purpose harness lead 27C (21) from air box heater switch (22) or glow plug switch (39). 0279 00-3 Change 1