TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 135 of 962

TM 9-2350-277-20-3 REPLACE BLOWER SWITCH (M577A3 AND M1068A3 ONLY) — Continued 0278 00 INSTALLATION 1. Install blower switch (7) on master switch panel (4). Secure with two screws (8). 2. Connect two circuit 59 leads (6) to blower switch (7). 3. Install master switch panel (4) on distribution box (5). Secure with eight screws (3), washers (2), and new locknuts (1). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0338 00). 2. Turn MASTER SWITCH to ON (see your -10). 3. Turn blower switch ON. Blower should run (see your -10). 4. Turn all switches to OFF (see your -10). END OF TASK 0278 00-3/4 blank