TM 9-2350-277-20-3 REPLACE REAR UTILITY RECEPTACLE CIRCUIT BREAKERS (M577A3 AND M1068A3 ONLY) — Continued 0276 00 INSTALLATION 1. Install circuit breaker (1) in distribution box (2). Secure with two screws (3) and nuts (4). 2. Install circuit breaker (5) in distribution box (2). Secure with two screws (3) and nuts (4). 3. Connect circuit 10 lead (6) and circuit 37A lead (7) to circuit breaker (1). 4. Connect circuit 37B lead (8) and circuit 10 lead (9) to circuit breaker (5). 5. Install master switch panel (10) on distribution box (2). Secure with eight screws (11), washers (12), and new locknuts (13). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0338 00). 2. Turn MASTER SWITCH ON (see your -10). 3. Check for power at utility outlet receptacles (see your -10). 4. Turn MASTER SWITCH OFF (see your -10). END OF TASK 0276 00-3/4 blank