TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 116 of 962

TM 9-2350-277-20-3 0270 00 18. Apply thin coat of adhesive sealant to one side of gasket (19) and to mounting surface of distribution box (4). Install gasket on distribution box. FOLLOW-THROUGH STEPS 1. Install master switch panel assembly (WP 0260 00). 2. Connect battery ground strap (WP 0337 00). END OF TASK 0270 00-8 Change 2 REPAIR DISTRIBUTION BOX (M113A3,M1059A3, M1064A3, AND M58 ONLY) — Continued