TM-9-2350-277-20-3 Unit Maintenance Manual Volume 3 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 104 of 962

TM 9-2350-277-20-3 REPLACE DISTRIBUTION BOX (M113A3,M1059A3, M1064A3, AND M58 ONLY) — Continued 0269 00 REMOVAL 1. Remove screw (1), lockwasher (2), leads 27E, 10, 15, (3), and 450A (4) from bus bar (5) of distribution box (6). Remove grommet (7). Discard lockwasher and grommet. 2. Remove lead 400 (8) from distribution box (6). 3. Remove circuit leads 2 (9), 2A (10), and two grommets (11) from distribution box (6). Discard grommets. NOTE Step 4 applies to M113A3 carriers with water/ration heater kit installed only. 4. Remove circuit lead 222B (12) and grommet (13) from distribution box (6). Discard grommet. 0269 00-2 Change 2