TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 66 of 790
TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 7) Fill transmission with approximately 36 quarts (refill capacity) or 57 quarts (initial fill) of OE/HDO or OEA, to bring level between FULL and ADD marks on gauge rod. See Transmission Lubrication Table (Table 3, page 0155 00-18). TRANSMISSION OIL LEVEL FULL MARK (DO NOT OVERFILL) 0155 00-46 Change 3