TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 0155 00-39 Change 3 11) Install driver’s compartment power plant access panel and secure carrier. 10) Stop engine (see your -10). TRANSMISSION OIL SAMPLE VALVE 8) Close sample valve and install dust cap. 9) Take oil sample from transmission in the same manner as in Steps 6a6 - 6a8. 12) Deliver sample bottles to the unit AOAP monitor. NOTE For location of nearest AOAP Laboratory and complete information about AOAP, refer to TB 43-0210. NOTE If AOAP laboratory is not available, drain engine oil and change filter element/gasket every 150 hours/1500 miles or semi-annually. Transmission oil should be drained and filter element/gaskets changed every 150 hours/1500 miles or semi-annually. See AOAP TB 43-0211