TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 522 of 790

TM 9-2350-277-20-2 REPLACE HAND THROTTLE CONTROL CABLE ASSEMBLY — Continued 0219 00 ADJUSTMENT 1. Loosen set screw (3). Push control cable handle (8) full forward. 2. Place accelerator pedal (9) in full closed throttle position. Tighten set screw (3) in collar (2). 3. Operate hand throttle control cable (1) and accelerator pedal. Check that control cable does not bind. FOLLOW-THROUGH STEPS 1. Install power plant front access cover (WP 0449 00). 2. Install driver’s power plant access panel (see your -10). 3. Close power plant front access door (see your -10). 4. Raise trim vane (see your -10). END OF TASK 0219 00-6