TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 479 of 790
TM 9-2350-277-20-2 REPLACE GLOW PLUG POWER HARNESS — Continued 0211 00 2. Connect glow plug power harness (1) on left side (4) of glow plug controller (5). 3. Remove nut (6) from ground terminal (7). Install blue ground lead (8), new lockwasher (9), and nut on ground terminal. 4. Remove nut (10) from switch terminal (11). Install orange switch lead (12), new lockwasher (13), and nut on switch terminal. 5. Remove nut (14) from battery terminal (15). Install red double lead (16), new lockwasher (17), and nut on battery terminal. FOLLOW-THROUGH STEPS 1. Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00). 2. Install power plant access panel (see your -10). 3. Install driver’s power plant access panel (see your -10). END OF TASK 0211 00-3/4 blank