TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 450 of 790
TM 9-2350-277-20-2 REPLACE AIR BOX HEATER IGNITION WIRE — Continued 0204 00 INSTALLATION 1. Connect ignition wire (1) to ignition unit (5). 2. Connect other end of ignition wire (1) to air box igniter (2). 3. Secure ignition wire (1) to air pump wiring harness (4) with two new tie straps (3). 4. Rotate solenoid receptacle (7) to original position. Tighten nut (6) 1/2 turn after contact. FOLLOW-THROUGH STEPS 1. Install power plant upper and lower rear access panels and support (see your -10). END OF TASK 0204 00-2