TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 278 of 790

TM 9-2350-277-20-2 DRAIN FUEL TANKS (M577A3 AND M1068A3 ONLY) — Continued 0178 00 WARNING Fuel flowing over a metal surface causes staic electricity. This will cause a spark unless the surface is grounded. NOTE Use wiping rag to wipe up any spilled fuel. 4. Attach a ground strap (5) between hull and container (4). 0178 00-2