TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 255 of 790
TM 9-2350-277-20-2 REPAIR AIR CLEANER RETAINER 0170 00 THIS WORK PACKAGE COVERS: Removal (page 0170 00-1). Installation (page 0170 00-1). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0926 00, Item 65) M a t e r i a l s / P a r t s Lockwasher (8) P e r s o n n e l R e q u i r e d Unit Mechanic R e f e r e n c e s See your -10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Trim vane lowered (see your -10) Power plant front access door open (see your -10) Air cleaner door removed (see your -10) REMOVAL 1. Release retainer handle (1) and slide out filter element (2). 2. Remove eight nuts (3), lockwashers (4), and screws (5) from retainer (6) and housing (7). Remove retainer from housing. Discard lockwashers. INSTALLATION 1. Position new retainer (6) into housing (7). Secure with eight screws (5), new lockwashers (4), and nuts (3). Tighten all nuts at this time. NOTE Check operation of retainer to make sure there is no binding during operation. If binding occurs, loosen screws and repeat Step 1. 2. Install filter element (2) and reset retainer handle (1). 0170 00-1