TM 9-2350-277-20-2 REMOVE/INSTALL POWER PLANT ASSEMBLY — Continued 0156 00 NOTE Make sure spacer plate (half ring) stays in right side of transmission mount when power plant assembly is removed. 26. Remove power plant assembly from carrier and place on blocks (WP 0157 00). Have helper assist. INSTALLATION WARNING Damaged lifting slings can fail with load. Soldiers can be killed or injured. Inspect all slings (WP 0673 00) before use. Do not use damaged slings. WARNING Hanging loads can kill or injure you. Keep away from hanging loads and overhead equipment. Keep hands out of compartment while power plant is being lifted for removal or lowered for installation. 1. Attach power plant lifting sling (3) to power plant. Have helper assist. 0156 00-13 Change 2