TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 198 of 790

TM 9-2350-277-20-2 REMOVE/INSTALL POWER PLANT ASSEMBLY — Continued 0156 00 WARNING Damaged lifting slings can fail with load. Soldiers can be killed or injured. Inspect all slings (WP 0673 00) before use. Do not use damaged slings. WARNING Hanging loads can kill or injure you. Keep away from hanging loads and overhead equipment. Keep hands out of compartment while power plant is being lifted for removal or lowered for installation. 25. Attach power plant sling (3) to lifting brackets (4) and lift power plant assembly. Have helper assist. 0156 00-12 Change 2