TM-9-2350-277-20-2 Unit Maintenance Manual Volume 2 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 182 of 790
TM 9-2350-277-20-2 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0155 00 Table 19. Annual Unit Level Preventive Maintenance Checks and Services for M113A3 FOV ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED C R E W M E M B E R PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 105 Annual 0.1 Carrier a. Lubricate tachometer and speedometer shafts annually with GIA. See Tachometer and Speedometer Shaft Lubrication Table (Table 11, page 0155 00-26). 1) Disconnect shafts at both ends (WP 0432 00), remove slotted washers from drive ends of cores, and remove cores from instrument panel end of shafts. Clean and lubricate cores with GIA, insert cores in shafts. Install slotted washers, and connect both end of shafts. If tachometer adapter has a grease fitting, lubricate sparingly with lubricant GIA. b. Clean, inspect and lubricate cores. Insert cores in shafts. Install slotted washers and connect both ends of shafts. If tachometer adapter has a grease fitting, lubricate sparingly with GIA. SPEEDOMETER SHAFT TACHOMETER SHAFT 0155 00-162 Change 3